Q-LAB CORPORATION

Q-SUN XE-8 XENON TEST CHAMBER GEN 4

Mã sản phẩm: XE-8G4

The Q-SUN Xe-8 is the NEW standard in large capacity, rotating rack xenon arc weathering testers.

The Q-SUN Xe-8 tester offers greater capacity, lower price, and significantly longer lamp life than leading competitors, in addition to its unmatched technical capabilities.

The versatile Q-SUN Xe-8 tester is the simplest, most reliable, and easiest-to-use large-capacity rotating rack xenon arc tester available

Share

Q-SUN XE-8 XENON TEST CHAMBER GEN 4

 

v XENON ARC LAMPS FOR FULL-SPECTRUM LIGHT

The Q-SUN Xe-8 tester’s xenon arc lamps produce the most realistic reproduction of full-spectrum sunlight, including ultraviolet, visible light, and infrared radiation. For many materials, exposure to the full spectrum is necessary to provide an accurate simulation, especially when testing for color change and lightfastness.

 

The Q-SUN Xe-8 tester uses four air-cooled LIGHT/YEAR xenon arc lamps. This significantly reduces operating and maintenance expenses compared to water-cooled lamps. Q-Lab’s LIGHT/YEAR lamps are warrantied for about 8000 hours of operation at normal irradiance, and about 1000 hours at high irradiance.

 

Changing the Xe-8 lamps is quick and easy – they are easily accessible from the front of the tester. Replacement only requires the user to open the chamber door, remove some specimens, and open the optical filter lantern for access. The lamps can then be simply lifted out of the tester and replaced.

 

 

Q-Lab also offers water-cooled replacement lamps for use in Atlas Weather-Ometer® models Ci35, Ci35A, Ci65, Ci65A, Ci4000, Ci4400, and Ci5000.

These low-cost water-cooled replacement lamps are guaranteed to have a comparable spectral power distribution to original lamps supplied by Atlas. The lamps meet a wide range of ISO, ASTM, SAE, and AATCC requirements.

 

 

v OPTICAL FILTERS

The Q-SUN Xe-8 model’s optical filter lanterns are designed to produce the spectra specified in many global weathering and lightfastness test standards. These standards apply to a variety of industries for outdoor applications, as well as interior applications where sunlight where sunlight is filtered by window glass. The lanterns consist of an inner quartz glass cylinder and two sets of six outer filters, arranged in a two-tier hexagon. The performance of Q-Lab's filters does not decline with age; therefore, filters do not need to be replaced under normal operation. The only exception to this is the Window-IR filter, which requires regular replacement.

 

 

v TEMPERATURE MONITORING & CONTROL

Control of temperature is important because it influences the rate of degradation. Specimen exposure temperature is precisely controlled in the Q-SUN Xe-8 tester using black panel and chamber air temperature sensors. Both black panel and uninsulated onboard black panels are included standard with each tester, with top and bottom panels of each type to ensure temperature uniformity. The temperature can be set at any point between 45 °C and 105 °C, depending upon whether the black panel sensor is insulated or uninsulated, as well as irradiance level, filter type, lamp age, and ambient room temperature.

 

v HIGH SPECIMEN CAPACITY

The Q-SUN Xe-8 xenon arc tester offers a huge-capacity, industry-leading rotating rack. It supports 164 specimens of 51 × 102 mm (2.0 × 4.0”) or 96 specimens of 67 × 145 mm (2.6 × 5.7”) each.

 

 

v SOLAR EYE IRRADIANCE CONTROL

The SOLAR EYE irradiance control system constantly monitors and controls lamp output. This assures precise light exposure and maximizes reproducibility of test results. Irradiance control is available at 340 nm, 420 nm, or TUV (Total UV, 300-400 nm). All three control points are standard on the Xe-8 tri band sensor array.

 

v HUMIDITY CONTROL

Relative humidity (RH) control is standard in the Q-SUN Xe-8 tester. It allows the user to simultaneously control and display RH, black panel temperature, and chamber air temperature. Note that purified water is required for proper operation of the RH system in the Xe-8 tester.

 

v WATER SPRAY (FRONT AND BACK)

Outdoor moisture attack is simulated via pure water spray in the Xe-8 tester. Two spray nozzles located in the chamber can be programmed to operate during either the dark or light cycle. The ability to spray the backs of specimens is required by some SAE test methods and is also standard for the Xe-8. Note that purified water is required for proper operation of the water spray system in the Q-SUN Xe-8.

 

v CONTROLS & OPTIONAL SOFTWARE

The Q-SUN Xe-8 tester’s displays are designed to be both functional and easy-to-use. Q-SUN testers feature dual, full-color touchscreen displays and can be programmed in 17 user-selectable languages (English, French, Spanish, Italian, German, Chinese, Korean, Japanese, Czech, Dutch, Polish, Portuguese, Russian, Swedish, Thai, Turkish, and Vietnamese). This system includes complete self-diagnostic error checking, constantly monitoring the status and performance of all systems. It also displays tester error messages and routine service reminders as needed. The multicolor LED status indicator light updates users on the tester’s operational state at a glance.

 

An external USB port on every Q-SUN Xe-8 tester allows users to perform software upgrades quickly to address key performance issues. For quality systems that require documented proof of test conditions, this USB port can also be used to download tester performance history. Data from the USB export can be emailed directly to Q-Lab's technical support desk for expert troubleshooting and diagnostics. Performance information is also available via on-screen VIRTUAL STRIPCHART datalogging.

 

 

v CALIBRATION

Temperature Calibration

The Q-SUN Xe-8 onboard insulated and uninsulated black panel temperature sensors need to be calibrated periodically by the user. This assures accurate and consistent results.

 

Calibrating the Xe-8 black panel and black standard temperature sensors is simple using the Universal Calibrator system’s UC80 calibrated temperature sensors. UC80 calibration sensor arrays include both black panel and insulated black panel sensors of the same design as the Q-SUN Xe-8's onboard sensors. The low-cost, combination relative humidity/chamber air temperature sensor is designed to be replaced once a year by the user and cannot be recalibrated.

 

Irradiance Calibration

The Q-SUN Xe-8 onboard SOLAR EYE irradiance sensors need to be calibrated periodically by the user to assure accurate and consistent results.

 

Calibrating irradiance in the Q-SUN Xe-8 tester is simple using the Universal Calibrator system’s UC80 calibration sensor array, and takes only a few minutes. UC80 devices have the same standard 340 nm, 420 nm, and 300-400 nm TUV (Total UV) sensors as the Q-SUN Xe-8 tester’s onboard sensors.

 

 

ISO 17025 Accredited Recalibration

The UC80 itself needs to be returned to Q-Lab once per year for an inexpensive recalibration.

 

Q-Lab's calibration labs in the United States, Germany, United Kingdom, are ISO 17025 accredited by the American Association of Laboratory Accreditation (A2LA) to perform calibrations of UC sensors. Calibrations are traceable to the United States' National Institute of Standards and Technology (NIST).

 

v TEST METHODS AND STANDARDS:

Q-SUN Xe-8 xenon arc testers meet the specifications in nearly all major international, national, and industry test standards, including tests from ASTM, ISO, SAE, AATCC, IEC, and GB.

 

GENERAL

  • ASTM G155
  • MIL-STD-810H

AUTOMOTIVE

  • ASTM D7869
  • ISO 105-B06, -B10
  • JASO M346, M351
  • SAE J2412, J2527

PAINTS

  • ASTM D6695 
  • ISO 16474-2

TEXTILES

  • AATCC TM 16, 169
  • ISO 105-B02, -B04
  • Marks & Spencer  C9, C9A

PLASTICS

  • ASTM D2565   
  • ASTM D4459
  • ISO 4892-2

OTHERS

  • IEC 60068-2-5 (Photovoltaics)    
  • ASTM C1442 (Sealants)

 

Q-SUN XE-8 XENON TEST CHAMBER GEN 4

Other Products
Q-SUN XE-8 XENON TEST CHAMBER GEN 4
QCT CONDENSATION TESTER
Q-SUN XE-1 XENON TEST CHAMBER GEN 4
QUV ACCELERATED WEATHERING TESTER GEN 4
  • Công ty TNHH Thiết Bị & Hóa Chất Nguyễn Quỳnh Anh
  • Trụ sở chính:
  • 32/7 Ly Thuong Kiet St. – Ward 08 – Tan Binh Dist. – Ho Chi Minh City 
    Hotline: (+84) 982 74 74 36 - 0909 282 287 

  • Văn phòng kinh doanh:
  • 1/30 Nguyen Van Vinh St. - Ward 4 - Tan Binh Dist. - Ho Chi Minh City
    Tel: (84-28) 3948 22 77 - 3948 22 99 | Fax: (84-28) 38 11 72 72
    Email: sales@nqaco.com 

    Total counter: 949344 | Đang xem : 6