PARTICLE SIZE ANALYZER BETTERSIZER 2600
The Bettersizer 2600 is superior in the combination of Fourier and inverse Fourier designs. This smart design allows, on the one hand, the detection of scattered light in a very wide angular range from 0.016° to 165°. On the other hand, in contrast to the inverse Fourier design, the particles do not have to lie on one plane – the simultaneously accurate measurement of small and large particles is therefore achieved.
PARTICLE SIZE ANALYZER BETTERSIZER 2600
Particle size can be measured by either wet or dry method, using the Bettersizer 2600. A variety of applications have been covered by this versatile, powerful analyzer with its modular design and patented technologies. Users can characterize materials from 0.02 μm to 2600 μm, easily and accurately.
Features and Benefits
● Technology: Laser diffraction
● Particle size range: Wet dispersion: 0.02 to 2,600μm Dry dispersion: 0.1 to 2,600μm
● Wet and dry method of particle sizing is suitable for a wide variety of dispersing particle systems
● Precise measurement of both large and small particles covering the broadest range by a new patented technology utilizing both Fourier and Inversed Fourier optical systems
● Optical bench with 92 detectors covering an angular range of 0.016° - 165° Optional wet and/or dry dispersion
● Small volume dry dispersing module for small sample quantities especially for pharmaceutical or valuable samples in short supply
● Easy and fast to changeover between dispersing modules
● Easy to implement, create and use Standard Operation Procedures for new materials
Specification:
Bettersizer 2600 |
|
Particle size distribution |
Suspensions, emulsions, dry powders |
General |
|
Principle |
Laser diffraction technology |
Analysis |
Mie scattering theory and Fraunhofer diffraction theory |
Typical measurement time |
Less than 10 seconds |
Measurement performance |
|
Measuring range |
0.02 - 2600 μm (wet) * 0.1 - 2600 μm (dry) * |
Accuracy error |
≤ 0.5% * |
Repeatability |
≤ 0.5% * |
Number of size classes |
100 (user adjustable) |
Feeding mode |
Automatic circulation or micro cuvette (wet) Gas transportation (dry) |
Special functions |
SOP settings, refractive index measurement, sample ratio calculation |
Main device |
|
Optical system |
Combined Fourier and inverse Fourier & Tilted sample cell |
Laser |
High-power optical fiber laser (10 mW / 635 nm) |
Detector |
92 detectors (forward, lateral and backward arrangements) |
Measuring angle |
0.016 - 165° |
Wet dispersion module |
|
Measurement method |
One-click operation (automated measurement, cleaning, saving, printing, etc.) |
Dispersion medium |
Water or organic solvents (sample dependent) |
Circulation speed |
300 - 2500 r/min |
Ultrasonication |
Dry burning prevention,50 W |
Dry dispersion module |
|
Dispersion medium |
Air/ Nitrogen/Noble gas |
Air pressure |
0.1 - 0.8 MPa (Air compressor dependent) |
Software |
|
Conformity |
21 CFR Part 11, ISO 13320, USP <429> |
Reports |
Customizable reporting |
System parameters |
|
Dimensions (L x W x H) |
70.5 x 31.8 x 29.5 cm |
Weight |
23 kg |
Supply voltage |
100 - 240V, 50/60 Hz |
Computer configuration (recommended) |
|
Computer interface |
At least one high-speed USB 2.0 or USB 3.0 port required |
Operating system |
Windows 7 (32 bit and 64 bit) or higher |
Hardware specification |
Intel Core i5 Processor, 4GB RAM, 250GB HD, Wide screen monitor |
*Sample and sample preparation dependent |
PARTICLE SIZE ANALYZER BETTERSIZER 2600
32/7 Ly Thuong Kiet St. – Ward 08 – Tan Binh Dist. – Ho Chi Minh City
Hotline: (+84) 982 74 74 36 - 0909 282 287
1/30 Nguyen Van Vinh St. - Ward 4 - Tan Binh Dist. - Ho Chi Minh City
Tel: (84-28) 3948 22 77 - 3948 22 99 | Fax: (84-28) 38 11 72 72
Email: sales@nqaco.com